Learn more about our company our products duravent offers over twenty different product lines for residential.
Triple wall flue pipe clearance.
Our class a tiple wall chimney systems stay cool on the outside while providing a hot draft on the inside.
A straight up double wall flue pipe assembly.
Double wall stove pipe on the other hand requires only 8 inches of clearance from the ceiling and 6 inches from a wall.
Once these clearances are met you must convert your stove pipe to class a chimney pipe for proper venting of your stove.
We prioritize maintaining highest quality products and providing excellent service to our end customers and our distributors.
Also the maximum length of a double wall flue pipe assembly may be greater than is permitted for a single wall pipe.
Many think stovepipe can run from the wood stove right up through the ceiling and roof.
9 is a typical clearance between a gas fired boiler or furnace flue connector and combustibles.
Most of the double wall stove pipe allows for 6 clearance from wall combustibles and 8 from ceiling combustibles.
The roaring fire in the wood stove keeps the room toasty warm on a wet chilly night.
There are two general types of.
Fire clearances required range from 6 to 36 depending on the equipment.
Metal flue fire clearance requirements single wall metal pipe flues gas fired equipment.
To 6 in the closest clearance to a wall of any connector pipe.
Class a triple wall chimney systems are designed for easy installation feature a fire safe design to protect both the chimney the building.
See fire clearances single wall metal flues vents for the clearance from combustibles required for flue vent connectors these are not chimneys but rather the flue pipe smoke pipe or stack pipe that connects a heating appliance to a chimney.
This boosts stove efficiency by exhausting hot flue gases easily and efficiently.
This one is the sealed type.
All stove chimney pipe is chosen and classified by the inside diameter.
Can a triple wall flue pipe be used for a wood stove.
Duraplus chimney systems lock tightly with twist lock precision and require a 2 clearance to combustible materials.
Using a heat shield on a single wall stovepipe allows you to reduce the clearances from 18 to 6 to the wall and 9 to the ceiling.
Dvl s double wall air insulated design reduces clearances to combustibles from 18 in.
Dvl improves stove performance by maintaining high flue gas temperatures for a strong steady draft.
For example a single wall stove pipe requires 18 inches of clearance from ceilings or walls.
The minimum installation clearances for certified double wall flue pipes are much less than those for single wall pipes.